CVE-2025-9377
HighExploitedPublic exploitThe authenticated remote command execution (RCE) vulnerability exists in the Parental Control page on TP-Link Archer C7(EU) V2 and TL-WR841N/ND(MS) V9.
Published Aug 29, 2025 · Updated Feb 26, 2026
Key Facts
Patch immediately- CVE-2025-9377 is a high-severity vulnerability (CVSS 8.6 v4) affecting Archer C7 Firmware (Tp-Link), Tl-Wr841nd Firmware (Tp-Link), Tl-Wr841n Firmware (Tp-Link) and 2 more products.
- It is exploited in the wild, listed in CISA KEV, Industry KEV feed, CIRCL KEV, ENISA EUVD since Aug 29, 2025. Public exploit code is available.
- EPSS estimates a 38% probability of exploitation in the next 30 days.
- Fixed versions are available, including Archer C7(EU) V2 241108, TL-WR841N/ND(MS) V9 241108, Archer C7 Firmware 241108.
- Brandefense priority: patch immediately, because it is listed as exploited in the wild.
CVSS v4
8.6
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (30-day exploit likelihood)
38%
Higher than 98.5% of all scored CVEs
Exploited in the wild
Yes
4 catalog listings
Public exploit code
Available
Proof-of-concept or weaponized module
Get the full CVE-2025-9377 brief as a PDF
Every affected product and fixed release, exploitation status and a first 24 hours response checklist, emailed within minutes.
Description
The authenticated remote command execution (RCE) vulnerability exists in the Parental Control page on TP-Link Archer C7(EU) V2 and TL-WR841N/ND(MS) V9.
This issue affects Archer C7(EU) V2: before 241108 and TL-WR841N/ND(MS) V9: before 241108.
Both products have reached the status of EOL (end-of-life). It's recommending to
purchase the new product to ensure better performance and security. If replacement is not an option in the short term, please use the second reference link to download and install the patch(es).
Known-Exploited Catalog Listings
| Catalog | Added | Remediation due | Ransomware use |
|---|---|---|---|
| CISA KEV | Sep 3, 2025 | Sep 24, 2025 | Not reported |
| Industry KEV feed | Aug 29, 2025 | Sep 24, 2025 | Not reported |
| CIRCL KEV | Sep 3, 2025 | Sep 24, 2025 | Not reported |
| ENISA EUVD | Sep 3, 2025 | n/a | Not reported |
Required action: Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Affected Products
5 affected entries in total| Product | Affected versions | Fixed in |
|---|---|---|
| Archer C7 FirmwareTp-Link | See advisory | 241108 |
| Tl-Wr841nd FirmwareTp-Link | See advisory | 241108 |
| Tl-Wr841n FirmwareTp-Link | See advisory | 241108 |
| Archer C7(EU) V2 | See advisory | 241108 |
| TL-WR841N/ND(MS) V9 | See advisory | 241108 |
Patched Releases
Archer C7(EU) V2
241108
TL-WR841N/ND(MS) V9
241108
Archer C7 Firmware
241108
Tl-Wr841n Firmware
241108
Tl-Wr841nd Firmware
241108
Timeline
Publicly disclosed
Aug 29, 2025
Added to Industry KEV feed
Aug 29, 2025
Added to CISA KEV
Sep 3, 2025
Added to CIRCL KEV
Sep 3, 2025
Added to ENISA EUVD
Sep 3, 2025
Last updated
Feb 26, 2026
Weakness Type
- CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
- advisoryVulnCheck exploitation report
- exploitVulnCheck exploitation report
- exploitVulnCheck exploitation report
- exploitVulnCheck exploitation report
- exploitVulnCheck exploitation report
FAQ
Common Questions.
The authenticated remote command execution (RCE) vulnerability exists in the Parental Control page on TP-Link Archer C7(EU) V2 and TL-WR841N/ND(MS) V9.
Affected: Archer C7 Firmware (Tp-Link); Tl-Wr841nd Firmware (Tp-Link); Tl-Wr841n Firmware (Tp-Link), among others. The full list is in the CVE brief.
It is exploited in the wild, listed in CISA KEV, Industry KEV feed, CIRCL KEV, ENISA EUVD since Aug 29, 2025.
Yes. It was added on Sep 3, 2025 with a federal remediation due date of Sep 24, 2025.
Public exploit code is available.
Fixed versions are available, including Archer C7(EU) V2 241108, TL-WR841N/ND(MS) V9 241108, Archer C7 Firmware 241108.
Brandefense priority: patch immediately, because it is listed as exploited in the wild.
Is CVE-2025-9377 Running On Your Attack Surface?
Brandefense maps vulnerabilities like this one to your internet-facing assets and tells you exactly where to patch.
Request A Demo