CVE-2026-105484X6000R Command Injection
A security vulnerability has been detected in TOTOLINK X6000R 9.4.0cu.652_B20230116.
Published Oct 6, 2026 · Updated Oct 6, 2026 · Also known as EUVD-2026-92908, GHSA-34j5-jp28-25g9
Key Facts
Patch in the next maintenance window- CVE-2026-105484 is a critical-severity vulnerability (CVSS 10.0 v4) affecting X6000r Firmware (Totolink), X6000R.
- It is not listed in any known-exploited vulnerabilities catalog. No public exploit code is known.
- EPSS estimates a 2.1% probability of exploitation in the next 30 days.
- No fixed version is listed yet; check the vendor advisory for mitigations.
- Brandefense priority: patch in the next maintenance window, because of its high severity, although no exploitation is known.
Scores
CVSS v4
10.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X
EPSS (30-day exploit likelihood)
2.1%
Exploit maturity
Proof of concept
ATLAS score
34/100
Publication score, see How it works
Exploitation Verdict
KEV listed
Not listed
Federal due date
None
No federal due date
Ransomware use
Not reported
Attributed actors
None named
Exploit & Defence Guidance
Exploit maturity
Proof of concept
Public exploit code
1
Proof-of-concept links
In-the-wild evidence
0
Reports of active use
Description
A security vulnerability has been detected in TOTOLINK X6000R 9.4.0cu.652_B20230116. The impacted element is the function firmware_check of the file /cgi-bin/cstecgi.cgi of the component UploadFirmwareFile Handler. Such manipulation of the argument file_name leads to os command injection. The attack may be performed from remote.
Affected Products
2 affected entries in total| Product | Affected versions | Fixed in |
|---|---|---|
| X6000r FirmwareTotolink | See advisory | n/a |
| X6000R | See advisory | n/a |
Timeline
Publicly disclosed
Oct 6, 2026
Weakness Type
- CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
- CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
- otherCVE-2026-105484 | CVE Analysis and Report
- otherSubmit #984434 | TOTOLINK X6000R 9.4.0cu.652_B20230116 CWE-78 OS Command Injection
- otherVDB-413619 | TOTOLINK X6000R UploadFirmwareFile cstecgi.cgi firmware_check os command injection
- otherVDB-413619 | CTI Indicators (IOB, IOC, TTP, IOA)
- othertotolink.net
FAQ
Common Questions.
A security vulnerability has been detected in TOTOLINK X6000R 9.4.0cu.652_B20230116.
Affected: X6000r Firmware (Totolink); X6000R. The full list is in the CVE brief.
It is not listed in any known-exploited vulnerabilities catalog.
No, it is not currently listed in the CISA Known Exploited Vulnerabilities catalog.
No public exploit code is known.
No fixed version is listed yet; check the vendor advisory for mitigations.
Brandefense priority: patch in the next maintenance window, because of its high severity, although no exploitation is known.
Is CVE-2026-105484 On Your Attack Surface?
Brandefense matches it against the products discovered on your perimeter and opens a finding the day a CVE like this is listed.
Request A Demo