Skip to content
Vulnerability Intelligence

CVE-2025-34152

CriticalExploitedPublic exploit

An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint.

Published Aug 7, 2025 · Updated Apr 14, 2026

Key Facts

Patch immediately
  • CVE-2025-34152 is a critical-severity vulnerability (CVSS 9.4 v4) affecting M300 Wi-Fi Repeater.
  • It is exploited in the wild, listed in Industry KEV feed, CIRCL KEV since Aug 7, 2025. Public exploit code is available.
  • EPSS estimates a 87% probability of exploitation in the next 30 days.
  • No fixed version is listed yet; check the vendor advisory for mitigations.
  • Brandefense priority: patch immediately, because it is listed as exploited in the wild.

CVSS v4

9.4

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS (30-day exploit likelihood)

87%

Higher than 99.7% of all scored CVEs

Exploited in the wild

Yes

2 catalog listings

Public exploit code

Available

Proof-of-concept or weaponized module

Get the full CVE-2025-34152 brief as a PDF

Every affected product and fixed release, exploitation status and a first 24 hours response checklist, emailed within minutes.

Description

An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint. The input is processed by the internal date '-s' command without rebooting or disrupting HTTP service. Unlike other injection points, this vector allows remote compromise without triggering visible configuration changes.

Known-Exploited Catalog Listings

CatalogAddedRemediation dueRansomware use
Industry KEV feedSep 15, 2025n/aNot reported
CIRCL KEVAug 7, 2025n/aNot reported

Required action: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable.

Affected Products

1 affected entries in total
ProductAffected versionsFixed in
M300 Wi-Fi RepeaterSee advisoryn/a

Timeline

  1. Publicly disclosed

    Aug 7, 2025

  2. Added to CIRCL KEV

    Aug 7, 2025

  3. Added to Industry KEV feed

    Sep 15, 2025

  4. Last updated

    Apr 14, 2026

Weakness Type

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

References

4 more references in the full CVE brief

FAQ

Common Questions.

Is CVE-2025-34152 Running On Your Attack Surface?

Brandefense maps vulnerabilities like this one to your internet-facing assets and tells you exactly where to patch.

Request A Demo