In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability

Published Sep 1, 2022 · Updated Aug 3, 2024

Key Facts

Patch in the next maintenance window
  • CVE-2022-37130 is a critical-severity vulnerability (CVSS 9.8 v3.1) affecting Dir-816 Firmware (Dlink).
  • It is not listed in any known-exploited vulnerabilities catalog. No public exploit code is known.
  • EPSS estimates a 27% probability of exploitation in the next 30 days.
  • No fixed version is listed yet; check the vendor advisory for mitigations.
  • Brandefense priority: patch in the next maintenance window, because of its high severity, although no exploitation is known.

Scores

CVSS v3.1

9.8

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS (30-day exploit likelihood)

27%

Higher than 98.0% of all scored CVEs

Exploit maturity

Proof of concept

ATLAS score

44/100

Publication score, see How it works

Exploitation Verdict

KEV listed

Not listed

Federal due date

None

No federal due date

Ransomware use

Not reported

Attributed actors

None named

Exploit & Defence Guidance

Exploit maturity

Proof of concept

Public exploit code

1

Proof-of-concept links

In-the-wild evidence

0

Reports of active use

Description

In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability

Affected Products

1 affected entries in total
ProductAffected versionsFixed in
Dir-816 FirmwareDlink1.10cnb04n/a

Timeline

  1. Publicly disclosed

    Sep 1, 2022

  2. Last updated

    Aug 3, 2024

Weakness Type

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

References

1 more references in the full CVE brief