CVE-2022-37130Dir-816 Firmware OS Command Injection
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
Published Sep 1, 2022 · Updated Aug 3, 2024
Key Facts
Patch in the next maintenance window- CVE-2022-37130 is a critical-severity vulnerability (CVSS 9.8 v3.1) affecting Dir-816 Firmware (Dlink).
- It is not listed in any known-exploited vulnerabilities catalog. No public exploit code is known.
- EPSS estimates a 27% probability of exploitation in the next 30 days.
- No fixed version is listed yet; check the vendor advisory for mitigations.
- Brandefense priority: patch in the next maintenance window, because of its high severity, although no exploitation is known.
Scores
CVSS v3.1
9.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS (30-day exploit likelihood)
27%
Higher than 98.0% of all scored CVEs
Exploit maturity
Proof of concept
ATLAS score
44/100
Publication score, see How it works
Exploitation Verdict
KEV listed
Not listed
Federal due date
None
No federal due date
Ransomware use
Not reported
Attributed actors
None named
Exploit & Defence Guidance
Exploit maturity
Proof of concept
Public exploit code
1
Proof-of-concept links
In-the-wild evidence
0
Reports of active use
Advisories And Exploit References
Description
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
Affected Products
1 affected entries in total| Product | Affected versions | Fixed in |
|---|---|---|
| Dir-816 FirmwareDlink | 1.10cnb04 | n/a |
Timeline
Publicly disclosed
Sep 1, 2022
Last updated
Aug 3, 2024
Weakness Type
- CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
- advisoryweb.nvd.nist.gov · vuln
- advisorydlink.com · security-bulletin
- advisoryUSOM advisory
- advisoryweb.nvd.nist.gov · vuln
- advisoryweb.nvd.nist.gov · vuln
FAQ
Common Questions.
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
Affected: Dir-816 Firmware (Dlink) versions 1.10cnb04. The full list is in the CVE brief.
It is not listed in any known-exploited vulnerabilities catalog.
No, it is not currently listed in the CISA Known Exploited Vulnerabilities catalog.
No public exploit code is known.
No fixed version is listed yet; check the vendor advisory for mitigations.
Brandefense priority: patch in the next maintenance window, because of its high severity, although no exploitation is known.
Is CVE-2022-37130 On Your Attack Surface?
Brandefense matches it against the products discovered on your perimeter and opens a finding the day a CVE like this is listed.
Request A Demo