CVE-2018-19616Powermonitor 1000 Firmware Authentication Bypass
An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Published Dec 26, 2018 · Updated Nov 21, 2024
Key Facts
Patch immediately- CVE-2018-19616 is a high-severity vulnerability (CVSS 8.1 v3) affecting Powermonitor 1000 Firmware (Rockwellautomation).
- It is not listed in any known-exploited vulnerabilities catalog. Public exploit code is available.
- EPSS estimates a 30% probability of exploitation in the next 30 days.
- No fixed version is listed yet; check the vendor advisory for mitigations.
- Brandefense priority: patch immediately, because public exploit code exists for a high-severity flaw.
Scores
CVSS v3
8.1
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS (30-day exploit likelihood)
30%
Higher than 98.2% of all scored CVEs
Exploit maturity
Proof of concept
ATLAS score
41/100
Publication score, see How it works
Exploitation Verdict
KEV listed
Not listed
Federal due date
None
No federal due date
Ransomware use
Not reported
Attributed actors
None named
Exploit & Defence Guidance
Exploit maturity
Proof of concept
Public exploit code
1
Proof-of-concept links
In-the-wild evidence
0
Reports of active use
Advisories And Exploit References
Description
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Affected Products
1 affected entries in total| Product | Affected versions | Fixed in |
|---|---|---|
| Powermonitor 1000 FirmwareRockwellautomation | 1408-em3a-ent_b | n/a |
Timeline
Publicly disclosed
Dec 26, 2018
Last updated
Nov 21, 2024
Weakness Type
- CWE-287 Improper Authentication
References
- advisorypacketstormsecurity.com · Rockwell-Automation-Allen-Bradley-PowerMonitor-…
- advisoryics-cert.us-cert.gov · ICSA-19-050-04
- advisory45937
- advisory106333
- exploitExploitDB-45937
FAQ
Common Questions.
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000.
Affected: Powermonitor 1000 Firmware (Rockwellautomation) versions 1408-em3a-ent_b. The full list is in the CVE brief.
It is not listed in any known-exploited vulnerabilities catalog.
No, it is not currently listed in the CISA Known Exploited Vulnerabilities catalog.
Public exploit code is available.
No fixed version is listed yet; check the vendor advisory for mitigations.
Brandefense priority: patch immediately, because public exploit code exists for a high-severity flaw.
Is CVE-2018-19616 On Your Attack Surface?
Brandefense matches it against the products discovered on your perimeter and opens a finding the day a CVE like this is listed.
Request A Demo